Directions:
- Use
of rubber dam is recommended.
- Use
SNOOP as early in the cavity
preparation procedure as possible to avoid removing
too much tooth structure.
- Rinse
treatment area with water and dry.
- Hold
bottle vertically and dispense a drop of SNOOP
into a mixing well.
- Using
a small sponge or brush, carefully apply SNOOP
to the cavity for 10 seconds.
- After
10 seconds, rinse the cavity with water while applying
suction,
then dry.
- Remove
the stained dentin using either a low speed handpiece
with a round bur or an excavator.
- Repeat
procedure until no staining occurs.
|
|
|
|